Hello, When I tried to open a folder I have been working on for a while the application said 'insufficient memory to complete operation' and then 'abnormal...
BushFire32
Offline Send Email
Nov 23, 2007
12:46 am
396
I'm not sure what might have happened. I haven't experienced the problem you are describing, so I can't be sure the following will correct the problem but...
Kristen M. Harris
k34harris
Offline Send Email
Nov 23, 2007
3:28 pm
397
Dear all, It might be the after-effects of incompletely metabolized Christmas champagne but I have registered a whole serie of EM sections with a 10x error for...
t_launey
Offline Send Email
Dec 29, 2007
9:12 am
398
After you re-calibrate, I think that you can propagate to remaining sections to get all of them to the same size. Kristen M. Harris, PhD Professor,...
Kristen M. Harris
k34harris
Offline Send Email
Dec 30, 2007
2:30 am
399
Okay - here's what to do. I just tried it to remind myself. Go to the calibration section. Select all the traces, Set to the size you want. Then open the...
Kristen M. Harris
k34harris
Offline Send Email
Dec 30, 2007
2:38 am
400
Thank you for the answer, I am still having trouble and I not sure whether I am properly following your instructions. a) I went to "Section/List sections" b)...
t_launey
Offline Send Email
Dec 30, 2007
2:38 pm
401
How do you know what the pixel size is supposed to be? If you did a proper calibration, it should be correct. I'm a bit mystified, but I'll be interested to...
Kristen M. Harris
k34harris
Offline Send Email
Dec 30, 2007
8:13 pm
402
Hello, Initially, I usually ignore pixel size when importing the sections and I then immediately do a calibration before anything else, selecting the option...
t_launey
Offline Send Email
Jan 1, 2008
9:28 am
403
Hello everybody, can anyone tell me how I can measure the distance of individual immunogold particles to a reference point by using reconstruct? Thank you very...
daniel_neuroanatomy
daniel_neuro...
Offline Send Email
Jan 8, 2008
4:20 pm
404
Hi everybody, Following John's request, I just added an alternative link to download Reconstruct, the quick start guide, and the manual in the "Links" section...
zikopoul
Offline Send Email
Jan 25, 2008
3:42 pm
405
Thanks Basilis, If anyone has trouble, you may also download the last build from our website Synapse Web under tools located at synapses.clm.utexas.edu Kristen...
Kristen M. Harris
k34harris
Offline Send Email
Jan 25, 2008
4:07 pm
406
Hello, This email message is a notification to let you know that a file has been uploaded to the Files area of the reconstruct_users group. File :...
reconstruct_users@yah...
Send Email
Feb 16, 2008
4:09 pm
407
Hi everyone, I'm a new Reconstruct user. The lab where I was working at used the Neurolucida system with a motorised stage (Z- Axis) to capture image stacks...
fong.angelina
Offline Send Email
Feb 19, 2008
11:19 pm
408
If your images are already aligned, when you import them into Reconstruct they will remain aligned. Just lock the section and you won't 'unalign' them. You can...
Kristen M. Harris
k34harris
Offline Send Email
Feb 20, 2008
12:04 am
409
Hello, This is a 'calibration' question. I reconstructed structures from physical sections, at first without calibrating. I finally decided to analyse my...
louisecouton
Offline Send Email
Mar 6, 2008
3:01 pm
410
Hi, Is it possible to shift (i.e. translate left/right etc) whole image stacks once they've been imported into Reconstruct? And if so, is it possible to shift...
dconte83
Offline Send Email
May 14, 2008
3:23 pm
411
Hi Deborah: Chapter 10 on movements and alignments in the Reconstruct User manual may help here. There is information on aligning entire sections...
ksorra
Offline Send Email
May 22, 2008
9:07 pm
412
Hello, I need to rename a lot of objects in reconstruct, like dendrite01_Neuron02 to neur02_dend01, dendrite02_Neuron02 to neur02_dend02 .... I can do this...
t_launey
Offline Send Email
May 28, 2008
2:53 am
413
Doesn't look like you have a standard pattern to rename. The easiest what to do this is with rename in the object list, then all the traces associated with the...
Kristen M. Harris
k34harris
Offline Send Email
May 28, 2008
2:58 am
414
Hello, I solved my problem with a keystroke/mouse movement logger (Smack 1.06). It records all keystrokes including Backspace, Ctrl-C, arrows,.... It even...
t_launey
Offline Send Email
May 28, 2008
8:07 am
415
Thanks Thomas - sounds very clever, we are in the process of updating the RECONSTRUCT manual with all the FAQ's from the users group and cool things like this....
Kristen M. Harris
k34harris
Offline Send Email
May 28, 2008
12:33 pm
416
Thomas - could you share your actual macro so that we can see how you interfaced to RECONSTRUCT to perform this function? Thanks, Kristen M. Harris, PhD ...
Kristen M. Harris
k34harris
Offline Send Email
May 28, 2008
12:35 pm
417
Dear Dr. Harris, The actual macro depends on the position of the windows on the screen (it records mouse position) so would be of little use. Here is instead ...
t_launey
Offline Send Email
May 28, 2008
4:00 pm
418
I should add that the procedure probably work with many of the free/shareware/commercial macro recorders available. I tried Smack because it was the first on a...
t_launey
Offline Send Email
May 28, 2008
4:05 pm
419
Thanks Thomas. I have some mac-savvy and macro savvy folks in the lab who will appreciate this. Best, Kristen Kristen M. Harris, PhD Professor, Neurobiology ...
Kristen M. Harris
k34harris
Offline Send Email
May 29, 2008
1:50 am
420
I've just started using Reconstruct and made the mistake of not tracing all my traces in the same direction (clockwise). Is there a way to select a trace and...
matheson harris
mathesonmd
Offline Send Email
Aug 9, 2008
9:58 pm
421
Dear Mat, In the Trace menu, select "Reverse". You should also select "Automatically simplify new closed traces" in Serie/Options/Autotracing which takes care...
t_launey
Offline Send Email
Aug 10, 2008
5:59 am
422
Hi: One way that you can verify that a trace has a clockwise or counterclockwise (i.e. "reversed") orientation is by checking the area measurement in the...
ksorra
Offline Send Email
Aug 10, 2008
2:24 pm
423
Hi, I'm trying to obtain the value of the volume of some spines. I understand that the volume is computed using the Cavalieri formula, but my question is where...
r_villalba
Offline Send Email
Aug 13, 2008
7:43 pm
424
In the Object list - first go to series options>List>Objects>click on the values you want to display - in this case volume. Kristen M. Harris, PhD Professor,...
Kristen M. Harris
k34harris
Offline Send Email
Aug 13, 2008
7:47 pm