-----Original Message-----
From:
selmaware@yahoogroups.com [mailto:
selmaware@yahoogroups.com]On
Behalf Of Martin Hebel
Sent: Tuesday, November 07, 2006 5:56 PM
To:
selmaware@yahoogroups.com
Subject: RE: [StampPlot - Selmaware] Reset Plot at 0:00:00 Hours
Correction....
IFTH (RTIME),=,00:00:00,!RSET
-MH
Thank Jim,
I'm glad the new math is helping! You don't know how many times I
approached the math over the years and couldn't come up with a good way to
code it without wasting a bunch of processor time. The math was always a
big aggrevation for me when making macros, and if it was aggrevating to
me,
not sure how you all dealt with it!
With the reset, depending how often you check it, you can use an !IFTH
condition with time:
!IFTH [[(RTIME) > 00:00:00]*[(RTIME) < 00:00:10]],=,1, !RSET'
THis would give a 10 second window to check the time and reset. The
statement breaks down to:
IF (time > 00:00:00 AND time < 00:00:10) = 1 THEN !RSET
If you check at least once a second, it could be reduced to:
!IFTH (RTIME),>,00:00:00,!REST
Hope this helps,
Martin