Been doin some homework on the XBee to figure out if its going to fit my needs. I see that it has 5 ADC pins, do these need to be configured with the...
Using the right version of the XBee firmware (10A2), sending configuration information to the XBee can enable those ADC's and have them periodically send data...
Your everywhere Marten! haha, thanks for the info, I figured it was something that had to be configured with software and couldn't just be hardwired....
Now for the application boards, I was checking some out on the selmaware site. I'm looking for something not too bulky so I'm looking at the SIP, SIP-LV, and...
Steve, All the boards have extra solder holes for all the XBee pins, so beyond what is provided, you are free to add some lines. Beyond that, just ensure you...
I'm having trouble reading a value into BS2 from a Macro I created. Below is the code. SP: DEBUG "!READ (sldDuty)",CR SERIN 16,84,1000,Timeout,[DEC Duty] ...
And I was thinking, once its configured, use the two XBees that would be set up for transmission with the AppMod SIP for simplicity, but then again, I'm not...
I guess I'm just gonna go ahead and try to configure the ADC pin. I see that the pins available are pins 11 and 17-20. I would like to use either the SIP,...
Hi Duanne, You really can't mix binary with interactive control too well. When you send "!READ (sldDuty)",CR, StampPlot treats it as binary values with...
SelmaWare is pleased to announce the release of SelmaDAQ, Data Acquisition for Excel. SelmaDAQ Features: This is a data acquisition add-on tool for Microsoft...
Martin, Thanks! This is just in time for an upcoming project. R/Jay Respectfully, Jay K. Jeffries Andros Is., Bahamas A skimmer afloat is but a submarine, so...
Martin, Going to need some more help. I tried playing around by placing the !SEND (sldDuty) line in oAnalog object . Ahead and after the !ACNH statements...
Hi Duane, With this line, what are you trying to accomplish? DEBUG DEC ch0, ",(AINVAL0)",CR It's not the correct format for either plotting a channel or...
Thanks for the correction. I was wrongly attempting to assign Ch0 to AINVALo; along with incorrect syntax. There it is on page 8 in the Developer's Primer, it...
Great to hear! I know StampPlot isn't the most intuitive some times, so it's why I'm hear to help! Also, for simple plotting, the simplest method is: DEBUG...
This may seem like a stupid question, something I omitted, but for communication between the transceivers, is the prop plug the way to go? I need to configure...
hi Steve, You could either use the prop-plug or send it AT commands from your controller for configuration. The +++ stuff, just be sure to issue a ATWR to save...
So to configure the XBees, I could either plug then into the board of education and configure then through basic code or get ahold of the USB programmer to do...
Steve, There's 2 different issues: Configuring - you can use the BASIC Stamp and code, the PropPlug, or the USB Base, or a board from MaxSteam - search digikey...
Martin, I ordered a number of your xbee dev boards. I want to integrate this into my own custom design and was hoping you could provide schematics for the...
Hi Ryan, I've never done schematics on those boards, and the LV is very simply, just directly connecting the I/O. The LED's are from DIN and DOUT on the XBee,...
Hi Martin, I bought a new PC a couple of weeks ago and installed my Widcomm Bluetooth adapter software. I can quick connect to my eb500 from the task bar and...
Hi Stuart, I assume this is probably a vista OS? I haven't done any testing with Vista, so I'm not sure if that's the problem or not. StampPlot uses Microsoft...
Martin, Thanks for the input on the leds. I figured this was how you configured things but wanted to make sure. Ryan ... simply, ... on ... non- ... this ... ...
Hi Martin, No its only XP with a free option to upgrade to Vista. Luckily the Eb500 comms / StampPlot still works OK on my laptop though. For anyone who is...
Position Type Full time position Work Experience · Software Engineer (Must have 1 years experience) · Manager of Software Engineering (Nice to have 1-3...
Using the USB station, I'm unable to configure the XBee for analog transmission. I've been through ins and outs with the guys at maxstream and the only...
Hi Steve, I know no reason why. I know with the base firmware can be updated and configured. I have a friend who works with the API modes and analog a lot,...