527
Hi, I am using v3r7.9. I am having problems with the port speed. The max that is allowed in SPP is 56000. Why is it not 57600? Of course my laptop does not...
Joe
jtorelli76063
Offline Send Email
Dec 3, 2008
3:26 am
528
Hi Joe, Currently StampPlot uses Microsoft's MSCOMM32 control for serial communications. I am locked into the BAUD rates MS designed into this control and...
Martin Hebel
selmaware
Offline Send Email
Dec 3, 2008
3:31 am
529
Joe, The serial port also supports 128000 and 256000 that may be supported by your USB device. Try entering the baud rate manually as I don't list them in the...
Martin Hebel
selmaware
Offline Send Email
Dec 3, 2008
4:47 am
530
Is it possible to connect Stamp plot pro to a Basic stamp 1? Some applications don't require a BS2. I am new to this arena and was trying to connect but was...
mikeymummert
Offline Send Email
Dec 16, 2008
6:58 am
531
Hi Mike, I don't have much experience with the BS1, but as I understand i doesn't do serial data as easily. But, to be on the safe side you should post on the...
Martin Hebel
selmaware
Offline Send Email
Dec 16, 2008
6:59 am
532
... with ... IF they connect to the stamp plot with the Debug terminal you would think the BS1 would work as well, but I am haveing no luck...
mikeymummert
Offline Send Email
Dec 16, 2008
1:51 pm
533
No, it is not possible (at least not easily). The reason is, that BS1 DEBUG command doesn't send e.g. strings - they are stored in the Basic stamp Editor only....
Richard Balogh
rbalogh69
Offline Send Email
Dec 17, 2008
1:29 pm
534
Hi Martin, or other readers, Your help again please :) For a value of 0 to 500 the following works fine DEBUG SDEC Depth/100,".",SDEC2 Depth, CR 'Update plot...
Stuart Weightman
stuarttttt2000
Offline Send Email
Jan 14, 2009
9:01 pm
535
Hi Stuart, The BASIC Stamp does not perform division on signed values normally. There's a way you can save the sign (bit15), do the math on the absolute value,...
Martin Hebel
selmaware
Offline Send Email
Jan 14, 2009
10:04 pm
536
Hello Martin, Thanks for the pointers but despite trying for several hours I have still not cracked the problem. No doubt there is a way but I haven't found...
Stuart Weightman
stuarttttt2000
Offline Send Email
Jan 15, 2009
4:32 pm
537
Hi Stuart, Watch the quotes carefully, essentially you need to send: "[" SDEC Depth " \ 100]" CR so that stampplot gets the string of: [235 / 100] In code: ...
Martin Hebel
selmaware
Offline Send Email
Jan 15, 2009
5:29 pm
538
Sorry, just noticed I used \ and / for division. Of course it should be /. -Martin...
Martin Hebel
selmaware
Offline Send Email
Jan 15, 2009
7:45 pm
539
Hi Martin, Thanks for your perseverance, I missed or deleted those quotes somehow. DEBUG "[", SDEC Depth * -1, " / 100]",CR Works perfectly plotting 0 to...
Stuart Weightman
stuarttttt2000
Offline Send Email
Jan 16, 2009
4:42 pm
540
Hi All, I have an Atmel AVR board that is acquiring 3 analogue channels of data in real time under interrupt control (every 10.60ms). When the buffer is full,...
Mark
markaren10
Offline Send Email
Jan 19, 2009
10:37 am
541
Hi Mark, Do you want to try to code your AVR to draw the points and lines for the X-Y plotting, or did you want a macro to accept the data and do all the work...
Martin Hebel
selmaware
Offline Send Email
Jan 19, 2009
10:42 am
542
Hi Mark, Do you want to try to code your AVR to draw the points and lines for the X-Y plotting, or did you want a macro to accept the data and do all the work...
Martin_Hebel
selmaware
Offline Send Email
Jan 19, 2009
12:45 pm
543
Let me try to talk you through the X-YPlot macro, though you can do it in code as well. Filled circles are used in plotting the current point. !FCIR...
Martin Hebel
selmaware
Offline Send Email
Jan 19, 2009
1:31 pm
544
Not sure if the first go made it, so this might be a repeat... Hi Martin, Thanks for taking the time with this one... I have spent quite some time trying out...
Mark
markaren10
Offline Send Email
Jan 20, 2009
1:06 pm
545
Hi Martin, I have spent quite some time trying out your updates and several variations. Interesting errors occur, but thankfully little smoke at the moment :) ...
Mark
markaren10
Offline Send Email
Jan 20, 2009
1:07 pm
546
Mark, I modified one thing, the !IFTH for the !LINE was broken up over 2 lines instead of being one line (Email line length issue when I posted), and your...
Martin Hebel
selmaware
Offline Send Email
Jan 20, 2009
1:22 pm
547
Many Thanks, Mark ... at ... SETD ... section ... sections ... can do ... I use ... of ... You ... modify to ... has ... values, ... with ... lines ... and ......
Mark
markaren10
Offline Send Email
Jan 20, 2009
5:43 pm
548
I am trying to send data to StampPlot from a temperature sensor (phidgets.com/products.php?product_id=1051) using their TCP gateway. Everything is on one...
peterh0mer
Offline Send Email
Feb 22, 2009
5:54 pm
549
Hi Peter, The first step is to get data plotted directly without TCP. The help files and tutorials are pretty clear on how the data needs to formatted. Not...
Martin Hebel
selmaware
Offline Send Email
Feb 22, 2009
6:00 pm
550
Wow, quick reply - Thanks Martin! I will look again at the docs. One question - does StampPlot passively receive data broadcast by port, or does it actively...
peterh0mer
Offline Send Email
Feb 22, 2009
8:25 pm
551
Hi Peter, normally passive looking for properly formatted stings. A timer can be set up if needed to send a request. Without knowing what is possible with the...
Martin Hebel
selmaware
Offline Send Email
Feb 22, 2009
8:28 pm
552
That there are no posts on this makes me think i am missing something basic. Com15 is the highest available com port in PLX: my data is coming in on COM32 in...
rhuggins42
Offline Send Email
May 21, 2009
4:46 pm
553
Hi, We are using MSCOMM from Microsoft, and it was designed for only up to COM15. You can change COM port numbers by going to Device Manager, select device,...
Martin Hebel
selmaware
Offline Send Email
May 21, 2009
4:55 pm
554
Hello, Can I have some help regarding comms please. Comms from StampPlot GUI to my ROV via (54 mteres of cat5) became unreliable (possibly due to slips rings...
Stuart Weightman
stuarttttt2000
Offline Send Email
Jul 11, 2009
12:02 pm
555
Stuart, You may want to post this question to the Parallax Basic Stamp forum at: http://forums.parallax.com/forums/default.aspx?f=5 phil ... From: "Stuart...
phil kenny
philk27182002
Offline Send Email
Jul 11, 2009
3:02 pm
556
Yes thanks Phil that was my next plan. However, looks like the converter(s) are u/s. I'll get another two, bettter quality perhaps and try again. Stuart...
Stuarttttt@...
stuarttttt2000
Offline Send Email
Jul 12, 2009
3:56 pm