Hi all, Does the serial port tester support subnet mask setting? Variable length subnet masking is common, I am hoping SP has an easy way of setting subnet...
I am trying to change the SP IP address from my attached micro. I can communicate fine with SP. When I send a new IP address (eg. 192.168.254.5) to FFE6h-FFE9h...
Alright I just got the developement kit today but won't get to play with it till tommorrow. I have some questions on how I might be able to use this. First, I...
I need help with serial communication between the SitePlayer and a Parallax Basic Stamp2. I know I must be missing something obvious, but I've been working at...
Anyone know what the preferred reset circuitry for the reset pin is? The Dev. kit schematic shows an elaborate circuit for the reset button. I don't need a...
I would like to drive a PWM output with digitized audio from the Ethernet. 1) Is that correct that this can be done with the current firmware using UPD...
The SP Software Manual makes reference to being able to perform serial communications to the SP without using a serial port on the microcontroller by "Bit...
O.k. so I was a little worse for wear - wanted to set the ip's of half a doz units. So I set the first, already working for weeks, to 90.0.0.a1.!! Don't ask...
I purchased a SP development kit a couple of months ago. I am simply a newbie hobbiest. I'm sure that mine are simple problems to most of you, but I am pulling...
I'm trying to design a data-logging unit that stores data in an SPI EEPROM (such as a 25LC640). I want to be able to fetch data from the eeprom into...
Has anybody run into this? I have a zywall firewall. I want to punch a hole in it so I can hit the siteplayer from the internet. I fiddle with the firewall...
I am having trouble using $SitePassword "mypassword" according to page 8 of the software manual. I put a empty file named PasswordRequired in the folder for...
Since it seems that there's no fixed interval timer available in SitePlayer, if I want to send digitized PWM data from an Ethernet to the PWM port on...
Greetings all, It just occured to me that there are some major security issues around using Siteplayer in a live/production environment... My biggest concern...
Re: CAN DO THAT message: Apparently my computer has been infected with a virus which is sending itself automatically. The virus is reported to be the...
When the DHCP option is active, on power-up Siteplayer looks for a DHCP server in order to receive an I.P address right ??? 1) What is the mechanism for...
Hello all, Oi, I really hope someone proves me wrong on my last post... I just realized that even worse than mucking up an external SPI device, one could...
I am trying to connect a BS2sx to the SitePlayer and am having trouble. I am trying to simply read whether the led on SitePlayer port IO3 ($FF14) is ON or OFF....
FWIW, my mail server just now intercepted a message to/from this list with the PE_Magistr.A virus in an attachment. It was attached to the junk message...
Greetings all, I was just digging through my semicondutor stockpile, and found some New Old stock... Mfg: Valor (now Pulse Engineering) Part: PT3877 10BaseT...
Hi: I want to pull the IO3 pin low and I used the following html command: <a href="pi.spi?IO3=0">Test</a> However, I don't see IO3 going low in my scope. Any...
Having started knowing little about udp protocol, apart from the fact that it might fulfill a need to operate multiple sp's simultaneously, after a few hours...
Hi all, I need help in suggestions on what I can connect to with site player? Cause this is for my school final year project. I so far have created a relay...
I have a site player running for 3 months, suddenly, i can't reach them via tcp. A test led (blinks by program) attached to the sp blinks.I restart it, and the...
Okay, I don't get it. My design is currently calling out a Site Player and an embedded processor. I want to use the Site Player as an Ethernet port so that I...
Assuming the ability to write ASM for the siteplayer, does anyone have any idea as to whether it'd be fast enough to turn into an ethernet-attached audio...
Hi How do I get my sitplayer to make connect to: http://dyndns.dk/opdat?name=caroe&pw=XXXX&silent=1 ? It is for opdating my siteplayer dynamic IP Best regards,...
Required - say 30 packets of 5 byte spi data, with 'accurate39; intervals between packets of say 5mS to 1 second. Java Ontimeout() not too bad to use, but relies...
Hello I bought the SitePlayer Development system about 6 months ago but just fired it up. When I first turned the system on everything worked fine. I could see...