Hi All, I have noticed that many people on this group have had problems with dead SPs. What kind of work area do you use? Do you have carpeting? A cloth ...
I only work at a full staitic controlled workstation. All production here is done at static controlled work stations. Also we install the SP's last just before...
Just a suggestion to the powers that be: It would sure be nice on future development boards to make it easier to bypass the ST232 level converter. Perhaps by...
hi ive built a project with an 8051 and max232 chip which are supposed to transmit the current temperature to the siteplayer. i have used c code to program my...
... Code looks ok, I would look at your hardware, or baudrate. Have you scoped out the data leaving the Chip, Level Converter etc. to be sure of levels and...
I've been using "realterm" to look at serial I/O rather than hyperterminal. It's easier to send and display binary codes than hyperterminal. It's free at: ...
... which are supposed to ... i have used c code ... code to transmit to ... siteplayer to ... sent ... 0h to ffh ... hex numbers being ... numbers using the ...
well a couple of things come to mind . . . a) I imagine TI is a transmit interrupt and SBUF is a serial buffer on the 8051 (I don't do those machines as of...
thanks for your input ... well a couple of things come to mind . . . a) I imagine TI is a transmit interrupt and SBUF is a serial buffer on the 8051 (I don't...
... Yahoo! Security Centre. http://uk.security.yahoo.com Another thing I just thought of. The SP needs a 3 to 4 second delay before it can accept serial data. ...
Hello All, It's been a while but I have a demonstration of a current project coming up and I'd really like to be able to knock some socks off. Here is the...
Plenty of help on this stuff to be found. Found this after only a few seconds on Google. http://www.quiksoft.com/newsletter/issue003/ Good luck with it John ...
Thanks Garry! Didn't know it was going to be that easy to find. I usually end up searching on the wrong terms. Now that you've pointed me in the right ...
I have a page called p2.htm that has the following link (copied from factory site: index.htm) for toggling the red led. factory.spi?io3=^io3~1 this toggles the...
... the LED doesn't toggle. ... Sorry, the actual behavior I'm seeing is the p2.htm file being reloaded (correctly), it's the LED toggle link that doesn't...
... Or try forcing a reload. With Netscape and Firefox you could press and hold SHIFT while clicking the "Reload" button. Pressing SHIFT-CTRL-R will usually...
Thanks for the suggestion. I found the problem, Macromedia Dreamweaver was changing the link from "p2.spi?io4=^io4~1"> to "p2.spi?io4=%5Eio4%7E1"> The changed...
I have a PIC logging data into my SitePlayer. The PIC then commands the SitePlayer to send the data via UDPsend to a remote PC. This works in UDPSendTester....
Tim, I too have been searching for a solution to a similar problem. I use the SP module as an option on a Room Pressure Monitor unit that is widely used in...
At work we use MS Excel and DDE to get remote data. DDE stands for "Dynamic Data Exchange." Maybe it will work for you. Try this link for more info: ...
... conector EPJ9372? que no he encontrado ninguna referencia ... The manufacturer of the connector is: PCA ELECTRONICS, INC. 16799 SCHOENBORN ST. NORTH HILLS,...
... one ... The Siteplayer development board comes with an a.c. adapter. The adapter outputs 12vdc. On the board the 12vdc goes throught a 7805 voltage...
Just in case any of you are having problems connecting to your Siteplayer through a router, I will report this problem to you. Siteplayer and Netgear RT314 do...
Puedes encontrar información en http://www.eix.co.uk/Ethernet/ Un saludo. Kurt. ... conector EPJ9372? que no he encontrado ninguna referencia ... The...
Paul, Could you be using old firmware? This behavior was changed in SitePlayer a few years ago. v1.6 replies to arp requests with a 'reply'. We checked it...