hey to all: I have a siteplayer that works, I can ping it, it spits out the HTTP page, it takes serial com and displays the objects, everything looks normal...
hi, I am new with siteplayer, I have the old module. trying from the web page when pressing a button wants to turn on an I/O port for specific seconds and then...
... back off. ... duration in seconds) then press a button, how to make the I/O ping to go on for this entered seconds value then turn it back off ? ... The...
Hi , I was trying to connect my SP using an ordinary RJ-45 connector + an external 10/100 BaseT filter but with no sucess, so, i've been wondering if maybe...
Hola Sebastian. Yo lo he conectado sin problemas a aparatos 10/100 baseT. Quizá deberías verificar el conexionado de pines, no recuerdo si es derecho o...
Actually you could do it with javascript. So the page thats downloaded has a button. When pushed use an onclick handler to send the trequest to the siteplayer...
Hi, I was just wondering: if I'm using the RJ-45 connector with 10BaseT filters from PCA (ref. EPJ9372), do I have to use a crossover cable or just a regular...
The cross over cable depends on what you connect the other end of the siteplayer to. If you connect to a network hub or switch (a lot of dsl /cable routers are...
hi, has anyone worked with the RJ-45 connector from Bel Stewart, the ref. is SI-50170-F (datasheet: http://www.belfuse.com/Data/Datasheets/SI-50170-F.pdf) the...
I make excuses myself for very bad English I do not succeed to find the way protect the visualization or the access to the main page of the module thanks I...
thanks, is there a way to refresh the main webpage for a giving number of seconds! can I turn a led for that period then back off again? how it could be done? ...
The odds are that it is now on its default IP address of 192.168.?.? try setting sitelinker to default IP address and port (menu option) and remove password. ...
... Hi John; You probably already know that Page 18 of the SP Software Manual warns against Ethernet downloading while performing serial I/O transactions, but...
Hello Tony, I use the following at the top of my webpages, done in HTML, to refresh the page. Just put the page name in the place of the ZZZZZ. This will ...
Ok . . . so I don't have a siteplayer development board, never thought I needed one. So now I'm trying to do the serial communication, but just two serial...
The siteplayer module presents serial data at TTL levels (5V), the dev board has a level shifter that converts the signals to RS232 voltage levels +- 3-12V...
Another way to get a level convertor, a lot of PIC development boards (less than £20) have an RS232 level convertor on them. Then a couple of links between...
what is the device on the other end? or rather, what are the signal levels of RX and TX of the other device you are communicating with? kevin kc6pob ... ...
I've uploaded a circuit schematic (serial_converter.pdf) to the files section of this group depicting a bi-directional TTL to RS232 serial converter/interface...
thanks, yeah I think I have a couple MAX232 chips around here somewhere . . . I'll try that. My PC's IP is static, I can't ping the siteplayer, but when I...
a PC ... ____________________________________________________________________________________ Looking for last minute shopping deals? Find them fast with...
Hello! I just bought a Siteplayer SP1 today. Does anyone have any good suggestions for using this board? Ideally I would then need to have the widget present a...
Hi Greg, Are you seeking project suggestions for SitePlayer application (home automation, process control & monitoring, environmental control & monitoring,...
... Hello! More of the latter I should think. What I basically need is advice on the practical aspects, namely how to have the thing be connected. According to...