--- In ultimaserial_group@yahoogroups.com, "mayahlah" <mayahlah@y...>
wrote:
>
>
> I am trying to make a thrust stand using Labview. The system has a
> load cell to Aerocon Op-Amp translation card to the Dataq-194RS
> Module. I have tried to get Labview to recognize this setup and so
> far, I can't. I originally followed the directions to add the WinDaq
> softward as an ActiveX component. The pdf file downloaded from
> Dataq's site was not a help as I am using Labview 7.0. The other
> information that they gave also was out of date. So I followed the
> links and downloaded Ultimaserial yesterday. I am still not able to
> get Labview to recognize this data aquisition setup. Any suggestions?
>
>
> Mayah
I have built and installed many systems as you describe, one of them
using the Dataq 151 module. The code is very similar to the 194, you
only have to specify the module in the set-up parameters of the
UltimaSerial active-x call. I will try to attach an example to this
note.(first time leaving a note on this system, so I am not sure I
can. If I do not succeed in attaching an example, you can e-mail me
direct at dgcontrols@..., and I will direct send the
attachment to you.
Good luck
Dave