Is anyone else out there using the Honeywell station? I have a sample of the records.txt from the new software, in the raincount column, I am seeing numbers...
15237
wuhu_software
Oct 3, 2009 11:27 pm
Here is a new release with some minor enhancements. If you have a WS-23XX or WS-36XX and have a problem with the mystery "0.02 in" rainfall after a reboot, or...
15238
cfr301@...
cfr313
Oct 3, 2009 11:34 pm
Zip link gives a 404 error, the page is there but the zip giving an error Rick...
15239
Neil
clarkn71
Oct 3, 2009 11:42 pm
Same as I get. Neil...
15240
wuhu_software
Oct 4, 2009 1:44 am
Sorry, had a typo in the file name. It is posted now....
15241
Jon Golubiewski
flag_buff
Oct 4, 2009 8:30 am
Hi Dimitris, Thanks for the photos and write-up. Nice job! Jon G....
15242
Martin
mrtn_kstr
Oct 4, 2009 11:30 am
... Thanks for the update. ... "0.02 in" rainfall after a reboot, or other problems, let me know. Yes I have, and indeed had strange readings after a boot....
15243
Marek Dziedzic
dziedzicmj
Oct 4, 2009 12:07 pm
I am using WUHU with WS-2315. On occasion, the software reports 0F (-17.8C), instead of no data, when there is a communication problem between the console and...
15244
n7zef
Oct 4, 2009 12:07 pm
Howdy; Getting my station setup here, and I cannot find what mode the Peet Bros is to be in. I tried to do a search on the earlier message files, and even read...
15245
flag_buff
Oct 4, 2009 2:29 pm
Hi Everyone! I began writing this email to ask if anyone had come across a DIY lightning Detector that could be mapped on a PC. I ended up with a list of...
15246
wuhu_software
Oct 4, 2009 3:21 pm
The next time this happens, open up currdat.lst with notepad. I think you will find that is what HW is writing in there. If not, let me know....
15247
wuhu_software
Oct 4, 2009 3:23 pm
I am pretty sure it is supposed to be in Data Logging Mode. If that does not work, let me know....
15248
wuhu_software
Oct 4, 2009 3:34 pm
Thanks for the post. I put this post in to a text file in the files area under DIY projects. Mark Wyman was also working on a DIY lightning detector and...
15249
Neil
clarkn71
Oct 4, 2009 6:18 pm
Does anyone know if all the cables and sensors for the ws2310 and the ws 2317 are interchangeable? Neil...
15250
eugenraduoradea
Oct 4, 2009 7:09 pm
As far as I experienced everything is interchangeable for all the modells La Crosse 23XX, sensors, consoles, cables... some of the sensors like the wind sensor...
15251
wuhu_software
Oct 4, 2009 10:24 pm
I can confirm the rain gauge is compatible between the WS-23XX and the WS-36XX as they have the same exact board in them. I have also used a WS-2308 remote...
15252
Rich Brunnworth
ngrrfan
Oct 4, 2009 10:36 pm
Will the console recognize the 1-99% humidity range? Rich ... -- Rich...
15253
Mike Reed
n7zef
Oct 4, 2009 10:45 pm
Yes, that is what it is supposed to be in. The software does not tell you until you are setting it up and choose the Peet Bros settings. It would have been...
15254
wuhu_software
Oct 5, 2009 12:11 am
Actually, when you select the Peet Bros station type in the general settings, a Dialog box pops up with instructions. The first sentence says to use data...
15255
wuhu_software
Oct 5, 2009 12:14 am
Good question... If I had to guess, I would say that you need both a new console and a remote thermo, but that is only a guess. It is possible that the key is...
15256
KNHBRIST1
steve_03222
Oct 5, 2009 1:01 am
I have the old style and if my memory is correct, I asked LaCrosse tech folks about that and they said you would also need a new console to get the 1-99%. If...
15257
wuhu_software
Oct 5, 2009 1:06 am
One clue might be that I did run a WS-2308 with the old remote thermo type. It did work. I later swapped it out for the newer version and it was then full...
15258
Rich Brunnworth
ngrrfan
Oct 5, 2009 1:30 am
It's worth a try. Worst that can happen is it doesn't work. LOL Rich ... -- Rich...
15259
Rob Reab
robreab
Oct 5, 2009 1:50 am
Not sure about the accuracy but, my 2317 is about 1 year old and I've recorded a number of readings above 90%. FYI Rob Reab <HTML><a...
15260
wuhu_software
Oct 5, 2009 10:51 am
Ok, I forgot, my old WS-2310 must be one of the newer ones... I forgot about that. Both consoles do show 93% humidity, but looking back, that was a newer...
15261
lratcliff lratcliff
sparky2726
Oct 5, 2009 12:30 pm
Has anyone tried changing out the cables on the sencors on the Lacrosse gear with something a little more imune to RF? I was thinking of something like a...
15262
Rob Reab
robreab
Oct 5, 2009 2:01 pm
I think a quick search of this forum will give you lot's of results of people having success replacing cables with shielded-twisted pair cable. On that note,...
15263
Jerry Flanders
jflndrs
Oct 5, 2009 2:29 pm
Look up the specs on common cat-5 cable. I would expect high RFI immunity if you used it balanced as intended. I actually use a 80 foot length of it to carry...
15264
Jerry Flanders
jflndrs
Oct 5, 2009 2:43 pm
I should have also mentioned that I actually intended to wire up my Lacrosse 2315 with a run of cat-5 from the sensors to the console, but decided to keep it...
15266
lratcliff lratcliff
sparky2726
Oct 5, 2009 3:34 pm
Ok, I am not familure with the CAT5 cable, other than knowing what it is. How would I wire it up as ballanced. I understand what that means as far as RF feed...