Hi, I'm using floorplan to map the temperatures of different rooms using a TOM10. I see in the log it records the changes i.e temperature date and time of...
I've have being trying to write Raw script to check the alarm status of Comfort and run an autoscript dependent on the outcome. The autoscript is working fine,...
There are no graphing features at the moment although now you can do sql and/or database based globals, there should really be a way of making some graphics....
Hi, Could you check this line AlarmState=xap.GetText("mi4.homeseer.server.93:comfortplugin.modedesc") as the error seems to show it without quotes: ...
One of the tenets of xAP is that the applications and devices are distinct functional entities distributed around your network. As such you can them mix and...
Found a bug I think, the error persisted with and without the quotes, didn't clear until I restarted Floorplan. Is the debug not refreshing, or holding onto...
Hi, The debug window shows the last error that has occurred, the only thing that clears it, other than a restart, is a new error message. It would be very hard...
maybe the xplhal web front end code can give you some ideas... http://www.xpl.myby.co.uk/info/xplhalweb/ ... seen a ... happens ... fix it ... visible......
ok, nearly there: Mode: security off, user 1 mode: security off, user 1 if you use = between two strings then they must be identical, extra spaces and...
Ditto here! I'd be v interested too. I've now got the squeezebox 3, cracking bit of kit but haven't succeeded in getting messages to it yet. The current...
James, I've just found that using the old xFx slim connector causes a hard crash of floorplan! Tried it with both service and GUI versions on the same machine...
There is definitely a issue here with the double space between user and 1 AlarmState is -mode: security off, user 1- would imply there is no double space but...
Yep, that's got it working. Had to change "NightMode" to ".NightMode" as it's an autoscript. Looking at the modedesc messages in viewer, they all seem to have...
What ports/protocols need to be allowed through a PC based software firewall? Mine has just stopped allowing viewer and Intranet Launcher from working – I...
James, not sure I have understood the xAP HomeSeer plugin correctly! I am using HomeSeer 2.1.102.0 and Version 2.0.313 of the conduit. My BSC devices (Quasar...
Well that's not good! I presume you have a raw device setup to capture data from the Slimserver? Does that device trigger any script? If it does then could you...
Hi, You should be able to trigger events using 'Device Status change' or 'Device Value change' in HomeSeer. Could you let me know how you have the events...
Hi, if anybody is interested, I have added a Logical Concept diagram to my NodeZero Blog at: http://www.darrensgarage.com/Home/tabid/53/EntryID/8/Default.aspx ...
Now avaliable on www.erspearson.com is an all new xAP interface for Slim Devices SlimServer. The plug-in is entirely written in Perl (like SlimServer) and uses...
It's been a while since I did any asp... At the moment, I do not allow the ports of floorplan / switchboard etc out through my firewall, however it is...
I'm going to give Edwards connector a go, but for now here is a little more information. No raw devices connected to slimserver, "global.xsp" already exists. ...
Hi Edward, Since the Xap developers link doesn't seem to work for me, I thought I post my results here. I've installed your plugin into the program files/ ...
Ian, Are you running 6.50? I haven't checked if it is case sensitive but the folder I created was xAP. I have plug-ins set for on the fly loading but I did...
Hi, I've been playing with how the intranet ocx serves pages and I think have now a more reliable server. If anyone who has seen odd half served pages or other...